The Tank Is 60 Litres Short. Evaporation or Theft?

How fuel station accounting works in Uzbekistan: tank stock, dispenser meters, shift handover, fleet fuel cards, loss control and a shift reconciliation table.

The Tank Is 60 Litres Short. Evaporation or Theft?

The evening shift ends. The operator dips the tank, writes the figure in the logbook and does the maths. The books say 10,500 litres should be left. The dipstick shows 10,440. Where did 60 litres go? It was hot today, so maybe evaporation. Maybe a measurement error. Or maybe someone really took it.

If you are investing in fuel retail in Uzbekistan, has this question already landed on your desk from a site manager? This article explains how station accounting works on the ground. Tank stock, dispenser meters, shift handover, fleet fuel cards, and how to tell normal losses from theft — in plain language. At the end there is a shift reconciliation table you can hand to station managers tomorrow.

How a business system is designed overall is covered in the main guide to custom ERP development. Here we focus on fuel stations only.

Fuel accounting has three numbers, and they never match

A shop counts goods in units. Fuel is a liquid: its volume changes with temperature, you cannot see it in the tank, and thousands of litres move through a busy site every day. So every station lives with three numbers.

  1. Book stock. Opening stock + fuel received − fuel sold.
  2. Measured stock. What is physically in the tank, by dipstick or automatic gauge.
  3. Sales by money. Revenue from the fiscal register and payment terminals, converted into litres.

These three will never agree to the litre. That is normal. The job of the system is not to make the variance disappear. It is to measure it, explain it and flag it the moment it crosses a threshold.

Tank stock: dipsticks, gauges and temperature

A dipstick is a long metal rod lowered into the tank. It shows the fuel level in centimetres. Centimetres are converted into litres using a calibration table, drawn up separately for each tank, which shows how many litres correspond to each level.

Also read Did Your Machine Stop Without Warning Again? Running Planned Equipment Maintenance in an ERP Technology · 10 min

An automatic tank gauge is a probe permanently fitted inside the tank. It measures the level and often temperature and water at the bottom as well. With a gauge you see stock during the day and during deliveries, not only at shift change.

The biggest source of confusion is temperature. Fuel expands in heat and contracts in cold. Its mass stays the same, but the number of litres changes. Uzbekistan has large day–night temperature swings for much of the year, so the same fuel can show noticeably different volumes. If the fuel in a tanker is warmer or colder than the fuel in the tank, litres also "drift" at delivery.

That is why petroleum products are normally recorded with temperature and density (how much a litre weighs). With these, the system can convert volume to a standard reference temperature or account in kilograms. The exact method and loss norms follow your accounting policy and the regulations in force. Your local chief accountant should confirm them, and head office should know which method the local books use.

A practical rule: dip at the same time each day, in the same order, with dispensers stopped. Record level, temperature and density in one entry. Then variances become comparable across days and sites.

At dawn an operator pulls a dipstick from a tank hatch to measure the fuel level

Dispenser meters, payments and shift handover

A dispenser is the pump that fills the vehicle. Each nozzle has a cumulative meter that shows the total litres ever delivered through it and never resets. The difference between opening and closing readings is what the shift sold.

Now the money side, where Uzbekistan differs from many markets. Under a presidential decree signed on 10 December 2025, from 1 April 2026 filling stations may sell fuel to the public only for non-cash payment: bank cards or electronic payment systems. Check the current wording on lex.uz, as rules can be amended. Cash is gone, but reconciliation is not. Litres from the dispensers are now matched against online fiscal receipts and terminal reports. How fiscal receipts connect to inventory is explained in the article on ERP and online cash register integration.

At every handover, the system should build this reconciliation automatically:

  • Meter litres ↔ litres on receipts — Source: dispenser, fiscal register; What to check if it differs: fuel delivered without a receipt, voided receipts
  • Receipt total ↔ terminal and payment-system report — Source: register, bank or payment provider; What to check if it differs: refunds, duplicate receipts
  • Card and coupon litres ↔ customer limits — Source: fuel card system; What to check if it differs: fills above the limit, fuel for another vehicle
  • Book stock ↔ measured stock — Source: system, dipstick or gauge; What to check if it differs: temperature, measurement error, losses
  • Fuel received ↔ delivery note — Source: tanker, document; What to check if it differs: short delivery, temperature difference

The incoming operator accepts the shift only after this table is closed. Any variance is signed off by both operators. General rules for shift handover and cashier control are covered in cash register discipline.

Fleet fuel cards, coupons and corporate receivables

Much of a station's stable revenue comes from companies: taxi fleets, delivery services, construction firms. They fill up with a fuel card or coupons and settle at month end. Convenient, but it brings two accounting risks.

The first is limits. Each card gets a daily or monthly litre limit, allowed fuel types and a vehicle plate. If the system does not block fills above the limit, the customer will later dispute the invoice.

The second is receivables. If a customer prepaid, the balance falls with each fill. If they fill on credit, debt grows. Either way, balance, overdue debt and a monthly reconciliation statement for every customer should come out at one click. For a foreign-owned operator, this is also what your auditors will ask for first.

A hypothetical example: a taxi fleet takes cards for 40 vehicles. At month end its report shows one car filling twice a day against a norm of once. That may be the fleet's internal issue, not the station's error. But a report with exact time, dispenser and receipt settles the dispute in a day. How the customer side calculates fuel norms is described in fleet and fuel tracking.

Shift handover in the operator room: an envelope and keys pass to the next operator

Methane and propane: how CNG and LPG stations differ

Gas stations matter more in Uzbekistan than in many markets, because many local vehicles run on methane or propane. The logic is similar, but measurement is different.

At an LPG station (propane, liquefied gas), gas is stored as a liquid in a tank and stock is read by a level gauge. Propane density depends on temperature even more than petrol does, so temperature records are critical.

At a CNG station (methane, compressed gas), there is no tank to fill. Gas arrives by pipeline, is compressed and stored in high-pressure cylinder banks. The main reconciliation is cubic metres on the inlet meter ↔ cubic metres sold through dispensers. Part of the difference is process consumption, such as the compressor itself.

For the system the conclusion is simple: if one site sells petrol, propane and methane, each runs in its own unit of measure with its own reconciliation rule.

Natural losses versus theft: seeing the difference

All fuel loses a little during storage, delivery and dispensing: evaporation, product left in hoses, vapour escaping through the tank's breather (pressure-relief) valves. This is called natural loss. Its permitted amount is set by approved norms and depends on season, tank type and operation. Anything above the norm needs an explanation. Set your internal alert threshold from your own data: log variances for a month or two, then let the system flag days that fall outside the usual range.

Theft is usually small and regular. So look at patterns, not at a single shift. Warning signs:

  • shortages always fall on the same operator or shift;
  • one dispenser shows a constant small gap between its meter and receipts;
  • voided and refunded receipts are far more frequent than on other shifts;
  • delivery shortages repeat with the same driver or supplier;
  • the variance is larger at night, when there are few customers.

When the system groups every variance along these lines, management sees the pattern within a month. Other forms of staff misconduct and control points are collected in employee theft prevention.

The daily owner report: 7 numbers

Running a network gets much easier if the owner, or head office, sees one page every morning:

  1. litres sold and revenue by fuel type and site;
  2. tank stock and how many days it will last;
  3. book-versus-measured variance, in litres and per cent;
  4. variances by shift and responsible operator;
  5. number of voided and refunded receipts;
  6. corporate customer debt and cards near their limit;
  7. deliveries expected today.

Watch the third number on a daily chart. A one-day spike says less than a steady rise over a week.

Rolling out the system step by step

You do not need to switch everything on at once. A practical sequence:

  1. Master data. Tanks with calibration tables, dispensers, nozzles, fuel types.
  2. Shifts and dips. Meter readings and stock measurements entered every shift.
  3. Register and terminals. Fiscal and payment data loaded automatically, reconciliation built by the system.
  4. Deliveries. Delivery note, dips before and after unloading, temperature and density.
  5. Corporate customers. Cards, limits, receivables and monthly statements.
  6. Equipment integration. Tank gauges and the forecourt controller, where technically possible.

Run each step for two or three weeks. Move on once operators are used to the new routine. If you are rolling out across several acquired sites, pilot at one station first.

Conclusion

At a fuel station the litres never match perfectly, and that is not the problem. Not seeing the variance is. Measure tank stock together with temperature. Reconcile dispenser meters with receipts and terminals every shift. Put limits on corporate cards and track receivables. Group variances by operator, dispenser and shift. Then the question of the missing 60 litres closes with a clear answer instead of a guess.

Frequently asked questions

Can a single station run on spreadsheets instead of a system?

With one station and one or two tanks, a disciplined spreadsheet can work. The problem is that a spreadsheet never warns you and does not pull data from the fiscal register or payment terminals. Once you add fleet customers, fuel cards or a second site, manual reconciliation eats hours and errors multiply. For an investor building a network, it also gives head office no reliable view.

Is every shift shortage a sign of theft?

No. Small variances from temperature swings, measurement error and evaporation are normal. What matters is the direction of the variance and whether it repeats. A shortage that keeps appearing on the same shift, the same operator or the same dispenser is a signal to investigate.

Stations in Uzbekistan no longer take cash. Is cash control still relevant?

Yes, it simply changes form. Every shift, terminal and payment-system reports are reconciled against dispenser meters and online fiscal receipts. Variances can hide in refunds, voided receipts and sales recorded while the system was offline.

Do we need automatic tank gauges from day one?

Not to start: regular manual dipping done the same way every time works. Automatic gauges speed up measurement, show stock during the day and remove handwriting errors. If they can be integrated with the system, the benefit grows. When you acquire existing stations, check what is installed before budgeting replacements.

Building or acquiring a fuel station network in Uzbekistan?

We can review how tanks, dispensers and payments are reconciled at your sites today and calmly suggest where a system would pay back first.

Discuss fuel station accounting →

Let's work out where to start

Free consultation with a DORA specialist

Message on Telegram

Let's discuss your project

Leave your number and a specialist will get in touch.

Send a request via Telegram

Your details are used only to contact you.